MC12 OM RM EN 74-111-132 v1.03.doc Ver. 1.03 Page 14 of 47
6.7.3. Function 3 - Velocity
Value: Revolutions per minute (rpm).
Enter the required velocity.
Velocity range depends on tube size applied.
Range:
Tube Sizes
Max. Velocity
Max. acceleration
0.5 - 0.8 1.2 1.6
600
200
3.2
500
150
4.8 - 6.0 8.0
400
100
If a value outside the range is entered, the MC12 will automatically correct the value to the
closest value allowed and the operator has to accept it by pressing the <ENT> key.
The fastest filling will be carried out at the highest velocity setting but the velocity should
always be adjusted to suit the characteristics of the product and to reduce splashing or
foaming.
If the velocity is changed during a fill, the fill will be completed using the original parameters
and the new value will not be applied until the start of the next fill.
If the velocity is changed while using the unit as a pump, the drive will apply the new
parameters immediately. The change will be carried out at the acceleration or deceleration
entered in Function 4.
6.7.4. Function 4 - Acceleration/deceleration
Value: An integral number.
The filling can start and stop more or less abruptly.
This function offers a choice of values between 1 and 200 dependent on the tube size and
drive; 1 = slowest, 200 = fastest.
Tube Sizes
Max. Velocity
Max. acceleration
0.5 - 0.8 1.2 1.6
600
200
3.2
500
150
4.8 - 6.0 8.0
400
100
If a value outside the range is entered, the MC12 will automatically correct the value to the
closest value allowed and the operator has to accept it by pressing the <ENT> key.
The function is used for optimizing the filling according to the product and the shape of the
bottle.
Function 4 affects pumping as well as filling and calibration.
If the value of the parameter is changed during a fill or calibration, the new value will not be
applied until the start of the next fill or calibration.