Operators and Reference Manual
MC12
MC12 OM RM EN 74-111-132 v1.03.doc Ver. 1.03 Page 37 of 47
7.2 Terminate dispensing
When the filler has completed the number of fillings asked for in F6: it stops automatically. If
<GO> is pressed again, the filler completes the programmed number of fillings once more.
If you want to stop the fillings, before the programmed number has been completed, press
<STOP>, and the filler stops after completing the filling in progress.
The filling series can be completed by pressing <GO>.
If you want to stop IMMEDIATELY, also in the middle of a filling, press <STOP> twice, and
the filler stops immediately.
The filling series can be completed by pressing <disp.>+<GO>, and the interrupted filling are
counted in.
7.3 Continuous run
MC12 can also control a filler as a pump so the pump runs continuously.
The pumping is started by pressing <pump>+<GO>.
The filler starts with the entered acceleration and runs up to the required number of
revolutions per minute.
The filler runs at this velocity until stopped by pressing <STOP>.
In Function 11 the current uncalibrated flow can be read.
If an exact flow read-out is required, the system must be calibrated. This calibration shall be
made as indicated in the next paragraph .
It is recommended to use a rather long filling for this calibration of the flow value.