Operators and Reference Manual
MC12 OM RM EN 74-111-132 v1.03.doc Ver. 1.03 Page 20 of 47
6.7.20. Function 23 - Stop Log
This function stops the automatic logging of production data (Log).
When a production has been completed and the log has been active, the log should be
stopped before print-out.
If the log is active, an L will be visible at the right side of the prompt line.
Stop log by entering: <2>+<3>+<ENT>
When the function is entered, the MC12 will ask for confirmation that the log should stop by
prompting the user to enter (Y) for 'yes' and a (N) for 'no'. If <N> for 'no' is pressed, the MC12
will exit the function.
If <Y> for yes is pressed, the logging of data for the memory will be stopped.
6.7.21. Function 24 - Print Log
If a printer is connected, this function will start the printing of the log.
When the function is started, the MC12 will ask for confirmation that the log should be
printed by prompting the user to enter (Y) for 'yes' and (N) for 'no'.
If <N> for 'no' is pressed, the MC12 will exit the function.
If <Y> for 'yes' is pressed, the MC12 will prompt for Y/N decision regarding continuous log.
If <Y> for ‘yes’ is pressed, the incoming log will be printed out continuously. These log-data
will automatically be erased. This function can be used if MC12 is used together with a scale
and if there is a risk of overloading the log by generating many data.
If <N> is pressed, the complete log will be printed out and printer will stop at the end of log.
The printing is carried out as background printing, i.e. the MC12 can be operated while
printing takes place.
Stop the log stopped with function 23, and MC12 prints out the number of fillings and
accumulated volume recalibrations from balance as well as related average and standard
deviation for recalibration values.
If the MC12 is used with a balance (see function 49), the registered data from balance are
printed out as a part of log and the number.
Please be aware that specific gravity is printed only if the volume format is set to ml.