Operators and Reference Manual
MC12 OM RM EN 74-111-132 v1.03.doc Ver. 1.03 Page 46 of 47
11.5 External GO ( Arrow 5)
Pin 1. Input for start signal.
+5 +50 Vdc, min. 100 msec. Front triggered.
Pin 2. Output, +24 Vdc, max 250 mA.
Pin 3. Ground.
Pin 4. Status output, max. +50 Vdc, 250 mA.
Pin 4 is connected to 0V via a relay when a connected drive is dispensing or
pumping.
Pin 5. No connection.
11.6 RS-232/1 ( Arrow 6); RS-232/2 (Arrow 7)
11.7 Net ( Arrow 8)
The "net" socket is reserved for RS-485 communication with the connected drives.
Communication may only take place via original Flexicon cables.