EasyManua.ls Logo

Flexicon MC12 - Function 42 - Set Date

Default Icon
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operators and Reference Manual
MC12
MC12 OM RM EN 74-111-132 v1.03.doc Ver. 1.03 Page 26 of 47
F 1: Volume
F 2: Tube diameter
F 3: Velocity
F 4: Acceleration/
deceleration
F 5: Reversing
F 6: Batch size
F 7: Delay
F17: Timer 1
F18: Timer 2
F19: Timer 3
Calibration and recalibration should not be carried out under drive 0 but under the respective
drive numbers. See the chapter on calibration for further details.
Drive 0 in serial mode
The following parameters are system parameters and should therefore be entered under
drive 0:
F 1: Volume
F 3: Velocity
F 4: Acceleration/
deceleration
F 5: Reversing
F 6: Batch size
F 7: Delay
F17: Timer 1
F18: Timer 2
F19: Timer 3
Calibration
Recalibration
Function 2, tube diameter, is entered under the respective drives by entering F41 and drive
number. In this way the last drive may carry out only a small part of the total fill, providing a
small tube is selected for this drive.
6.7.32. Function 42 - Set date
The MC12 has a built-in electronic clock and calendar. With Function 42 the date can be set
in the following format: YY/MM/DD
YY = the year from 00 - 99
MM = the month from 01 - 12
DD = the day of the month from 01 - 31
The date is entered by first entering the year, then the month and finally the day.
Example: <4>+<2>+<ENT>+<1>+<2<ENT>+<0>+<7+ENT>+<1+<8> =2012-07-18
By pressing <ENT> the new date will be stored in the system.
The system calculates automatically the days of the month. If the date 07/06/31 is entered by
mistake, the system will correct the date when the clock changes from 23/59/59 to 00/00/00.
The system does NOT take Summer Time (daylight savings time) into account.