5 BlackflyS Physical Interface
5.9 Case Temperature and Heat Dissipation
You must provide sufficient heat dissipation to control the internal operating temperature of the camera.
The camera is equipped with an on-board temperature sensor.
n For cased models—It allows you to obtain the temperature of the camera board-level components. The sensor
measures the ambient temperature within the case.
n For board-level models—It allows you to obtain the temperature of the camera FPGA junction temperature. The
temperature must be kept under 100°C. Some models may not require heat sinking depending on the mode of
operation.
As a result of packing the camera electronics into a small space, the camera can become hot to the touch
when running. For cased models, this is expected behavior and will not damage the camera electronics. For
board-level models, the temperature must be kept under 100°C and therefore may require a heat sink to
avoid damage.
To reduce heat, use a cooling fan to set up a positive air flow around the camera, taking into consideration the following
precautions:
n Mount the camera on a heat sink, such as a camera mounting bracket, made out of a heat-conductive material
like aluminum. When designing a heat sink for a board-level model, respect the Keepout Layer—Board-level
Models.
n Make sure the flow of heat from the camera to the bracket is not blocked by a non-conductive material like
plastic.
n Make sure the camera has enough open space around it to facilitate the free flow of air.
To access temperature information:
n Query the GenICam Device Control feature DeviceTemperature.
For board-level models—Device temperature can be monitored in SpinView as follows:
n Select Device_Temperature_Selector Enum Node
n Set Device_Temperature_Selector Enum Node Value to Mainboard
n Read Device_Temperature Node
2/19/2019
©2015-2019 FLIR
Integrated Imaging
Solutions Inc.
All rights reserved.
FLIR Blackfly
®