REGULATION INSTRUCTIONS
42
P
ARAMETER
4
C
ENTRAL HEATING PUMP
6. Use buttons ‘+’ and ‘-‘ to modify the value of the
parameter:
00 = standard (3” overrun)
01 = permanent (always running)
7. Press and release button ‘S’ to confirm. The
parameter number (4) will appear on the display.
8. Switch off the appliance and switch it back on again
to render the new parameter operative.
P
ARAMETER
5
W
ATER HAMMER PREVENTION
6. Use buttons ‘+’ and ‘-‘ to modify the value of the
parameter:
00 = off
01 = on (default = 2”)
7. Press and release button ‘S’ to confirm. The
parameter number (5) will appear on the display.
8. Switch off the appliance and switch it back on again
to render the new parameter operative.
P
ARAMETER
6
C
ENTRAL HEATING TIMER
6. Use buttons ‘+’ and ‘-‘ to modify the value of the
parameter within the prescribed limits
00 = 0 x 5” = 0”
90 = 90 x 5” = 450” (7.5 min)
The default value is 36 = 180” = 3 min
7. Press and release button ‘S’ to confirm. The
parameter number (6) will appear on the display.
8. Switch off the appliance and switch it back on again
to render the new parameter operative.
6
36
01
5
4
00
S
S
S
S
S
S
120 60 Hz
120 60 Hz
120 60 Hz
120 60 Hz
120 60 Hz
120 60 Hz