MAINTENANCE INSTRUCTIONS
51
6.6 Draining the central heating system
If the need arises to drain the system, this can be done as follows:
Switch the system to WINTER” mode and ignite
the water heater.
Switch off the power supply to the water heater.
Wait for the water heater to cool down.
Connect a hosepipe to the system drain point and
locate the other end of the hose in a suitable
drainage system.
Open the system drain valve (see fig. 1).
Open the air vents on the radiators, starting with
the highest and moving down the system to the
lowest.
When the system has been drained, close the
radiator breather valves and the drain valve.
If only the water heater needs to be drained,
close the flow/return isolating valves on the
heating circuit and open the drain valve located at the bottom of the water heater on the pump manifold
(see fig. 1);
Draining the domestic hot water system
If there is a danger of freezing, the domestic hot water system should be drained. This can be done as follows:
Close the mains water supply valve.
Open all the hot and cold water taps.
On completion, close all the previously opened taps.
Fig. 1