5.3 Gas data
5.3.1 Technical data tables
Heating Power (kW - BTU/hr) – Fan frequency (Hz) diagram
Heating Power kw
Frequency Hz
180170160150140130120110
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
100
90
80
70
6050403020100
Natural gas(G20)
L.P.G. (G31)
Table no.1 - CO
2
Values
Gas type CO
2
%
Natural gas - G20 9.18
Liquid Propane Gas - G 31 10.3
Table no.2 - Frequency
Gas type Minimum (Hz) Maximum (Hz)
Natural gas - G20 55 164
Liquid Propane Gas - G 31 52 155
NATURAL GAS G20
LIQUID PROPANE GAS G31
Lower Wobbe index
(15°C; 1013 mbar)
MJ/Nm
3
45.67 70.69
Nominal Supply pressure
M
bar
-
psi
20
-
0.29
37
-
0.53
Consumption (
59
°
F
; 1
4.5 psi
)
m
3
/h
-
ft3h
3.6
-
127.1
2.64
-
93.21