Pour grout until level reaches top of dam.Pour grout until level reaches top of dam.
Allow drying sufficiently to prevent grout fromAllow drying sufficiently to prevent grout from
overflowing while completing the remaining grouting.overflowing while completing the remaining grouting.
Do not vibrate baseplate when grouting;Do not vibrate baseplate when grouting;
make sure baseplate is vented properly and all areasmake sure baseplate is vented properly and all areas
indicated on General Arrangement drawing areindicated on General Arrangement drawing are
thoroughly filled to prevent any resonant problems.thoroughly filled to prevent any resonant problems.
d) d)
When When
the the
grout grout
is is
thoroughly hardened, thoroughly hardened,
removeremove
the dam.the dam.
e) e)
Completely Completely
tighten tighten
the the
foundation foundation
bolts.bolts.
4.3.3 4.3.3
Grouting Grouting
method method
BB
a) a)
Prepare Prepare
foundation foundation
properly properly
as as
shown shown
in in
thethe
General Arrangement General Arrangement
Drawing. Drawing.
The bolt The bolt
holesholes
shall be tapered to the top.shall be tapered to the top.
Foundation and grouting descriptionFoundation and grouting description
b) b)
Build Build
a a
dam around dam around
the foundation the foundation
to containto contain
grout materials.grout materials.
c) c)
Grout Grout
the the
foundation foundation
bolt bolt
holes holes
as as
perper
manufacturer's instructions, ensure that the groutmanufacturer's instructions, ensure that the grout
fills all open space and eliminates all air pockets.fills all open space and eliminates all air pockets.
Before grouting leveling space andBefore grouting leveling space and
baseplate, check level of pads of baseplate in bothbaseplate, check level of pads of baseplate in both
directions and perform a rough shaft/couplingdirections and perform a rough shaft/coupling
alignment. Alignment after grout has set will not bealignment. Alignment after grout has set will not be
possible if above is not satisfactorily completed.possible if above is not satisfactorily completed.
d) d)
Grout Grout
leveling leveling
space space
and and
baseplate abaseplate a
s s
perper
manufacturer's instructions.manufacturer's instructions.
Holes are provided in the baseplate to permitHoles are provided in the baseplate to permit
pouring the grout and distributing. Vent holes arepouring the grout and distributing. Vent holes are
also provided in each compartment. Fill under thealso provided in each compartment. Fill under the
baseplate completely, stirring to assure properbaseplate completely, stirring to assure proper
distribution of the grout. Check to see that thedistribution of the grout. Check to see that the
grout flows under the edges of the baseplategrout flows under the edges of the baseplate
evenly.evenly.
Pour grout until level reaches top of dam.Pour grout until level reaches top of dam.
Allow drying sufficiently to prevent grout fromAllow drying sufficiently to prevent grout from
overflowing while completing the remaining grouting.overflowing while completing the remaining grouting.
Do not vibrate baseplate when grouting;Do not vibrate baseplate when grouting;
make sure baseplate is vented properly and all areasmake sure baseplate is vented properly and all areas
indicated on General Arrangement drawing areindicated on General Arrangement drawing are
thoroughly filled to prevent any resonant problems.thoroughly filled to prevent any resonant problems.
e) e)
When When
the the
grout grout
is is
thoroughly hathoroughly ha
rdened, removerdened, remove
the dam.the dam.
f) f)
Completely Completely
tightened tightened
the the
foundation foundation
bolts.bolts.
4.4 4.4
Initial Initial
alignmentalignment
4.4.1 4.4.1
Shaft/coupling Shaft/coupling
alignmentalignment
The following information regarding shaftThe following information regarding shaft
alignment is only offered as a general guideline.alignment is only offered as a general guideline.
Flowserve requires that all shaft alignment beFlowserve requires that all shaft alignment be
performed in accordance with specifications set forthperformed in accordance with specifications set forth
in Chapter 7,in Chapter 7,
Shaft AlignmentShaft Alignment
from APIfrom API
Recommended Practices 686/PIP REIE 686, FirstRecommended Practices 686/PIP REIE 686, First
Edition.Edition.
Shaft alignment must be correct forShaft alignment must be correct for
successful operation. Rapid wear, noise, vibrationsuccessful operation. Rapid wear, noise, vibration
and actual damage to the equipment may be causedand actual damage to the equipment may be caused
by shaft misalignment. The shafts must be alignedby shaft misalignment. The shafts must be aligned
within the limits given within this section.within the limits given within this section.
Adjustment to correct the alignment in oneAdjustment to correct the alignment in one
direction may alter the alignment in another direction.direction may alter the alignment in another direction.
Always check in all directions after making anyAlways check in all directions after making any
adjustment.adjustment.
Coupled equipment must be aligned to minimizeCoupled equipment must be aligned to minimize
unnecessary stresses in shafts, bearings andunnecessary stresses in shafts, bearings and
coupling. Flexible couplings will not compensate forcoupling. Flexible couplings will not compensate for
appreciable misalignment. Foundation settling,appreciable misalignment. Foundation settling,
thermal expansion or nozzle loads resulting inthermal expansion or nozzle loads resulting in
baseplate/foundation deflection and vibration duringbaseplate/foundation deflection and vibration during
FOUDNATIONFOUDNATION
CONCRETECONCRETE
FOUNDATION BOLTSFOUNDATION BOLTS
LEVELINGLEVELING
SCREWSCREW
GROUT BOLT HOLESGROUT BOLT HOLES
GROUT LEVELINGGROUT LEVELING
SPACESPACE
GROUTGROUT
BASEPLATEBASEPLATE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Flowserve DMXD and is the answer not in the manual?

Flowserve DMXD Specifications

General IconGeneral
BrandFlowserve
ModelDMXD
CategoryWater Pump
LanguageEnglish

Related product manuals