Precautions related to the Class 1 laser product within the FlowCam 8400 analyzer housing to prevent exposure.
Safety warnings regarding electrical shock, unexpected movement of the syringe pump/barrel, and equipment damage.
Describes the FlowCam 8000 Series Dynamic Imaging Particle Analyzer and its core functions.
Details the major components and their functions within the FlowCam system, including the syringe pump, camera, and software.
Explains the different objective lenses and flow cell options available for particle measurement.
Details the fluorescence system, including lasers, optics, and PMT detectors for particle analysis.
Lists the items included in the FlowCam analyzer shipping container.
Provides guidelines for selecting an optimal location and power supply for the FlowCam analyzer.
Instructions for unpacking and connecting the necessary computer peripherals like monitor, keyboard, and mouse.
Details how to connect keyboard, mouse, and monitor to the FlowCam analyzer's ports.
Step-by-step guide for powering on the FlowCam analyzer and initiating the startup process.
Instructions to inspect tubing connections within the analyzer for proper seating and security.
Guide on filling the cleaner and rinse bottles with appropriate solutions for analysis.
Precautions and procedures for handling, cleaning, and connecting the flow cell to prevent damage.
Instructions for installing and changing objective lenses on the FlowCam analyzer.
Procedure to change the objective lens magnification via the VisualSpreadsheet software.
Details the types of autofocus beads and the steps to perform the automatic focusing routine.
Guidance on positioning and aligning the flow cell using the positioning knob for optimal autofocus.
Steps for manually focusing the flow cell using the Setup and Focus tool.
Guidance on aligning the flow cell for manual focus using positioning controls and visual cues.
Instructions on using the Pump Control dialog to adjust flow rate and achieve clear particle images for focusing.
Introduction to the Context dialog and its various tabs for configuring analysis parameters.
Details settings within the Capture tab for defining particle capture parameters like distance and image saving options.
How to select the appropriate flow cell type in the Context dialog.
Settings for sample volume, flow rate, autoimage rate, and priming within the Fluidics tab.
Configuration of image filters, report generation, and classification settings.
Using the Notes tab for comments and defining stop conditions for analysis termination.
Setting parameters to automatically stop the analysis based on particle count, time, or volume.
Setting thresholds for particle acquisition and rejection in the FlowCam 8400 analyzer.
Steps to prepare for sample analysis, including setting stop conditions and running the analysis.
Procedure to flush the FlowCam system using the pump's flush feature.
Steps for manually cleaning and rinsing the FlowCam analyzer with cleanser and rinse solution.
How to set up automatic clean and rinse cycles at the end of sample analysis.
Setting up automatic clean and rinse cycles to run at the end of an analysis.
Procedure for safely shutting down the FlowCam analyzer and its components.
General guidelines for cleaning and rinsing the FlowCam analyzer after use.
Detailed instructions for cleaning and maintaining the flow cell, including specific warnings and best practices.
Maintenance checks for fluidics bottles and tubing connections to ensure proper function and integrity.
Maintenance procedures for the main analyzer unit, including cleaning the exterior.
Steps to use the Pump Controller dialog to initiate and complete a pump syringe change.
Instructions for cleaning the previous syringe and replacing it in its container.
Answers to common questions about cleaning clogged flow cells and refocusing after objective changes.
Addresses questions on analyzer calibration frequency and resetting fluid bottle levels.
Describes four types of training opportunities offered for FlowCam users.
Details the benefits and components of a preventive maintenance service for the FlowCam analyzer.
Explains the process and requirements for IOQ services for the FlowCam analyzer.
Outlines laboratory services including particle analysis and method development.
Provides contact details for customer support via email, phone, fax, and mail.