Table 1. Accuracy Specifications
Function Range Resolution
Accuracy
± ([% of Reading] + [Counts])
Model
DC millivolts 600.0 mV 0.1 mV 0.5 % + 2 110 PLUS, 115
DC Volts
6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
0.5 % + 2 110 PLUS, 115
DC, 45 to 500 Hz 500 Hz to 1 kHz
Auto-V LoZ
[1]
True-rms 600.0 V 0.1 V 2.0 % + 3 4.0 % + 3 110 PLUS
45 to 500 Hz 500 Hz to 1 kHz
AC millivolts
[1]
True-rms 600.0 mV 0.1 mV 1.0 % + 3 2.0 % + 3 110 PLUS, 115
AC Volts
[1]
True-rms
6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
1.0 % + 3 2.0 % + 3 110 PLUS, 115