True-rms Multimeters
General Specifications
23
Table 1. Accuracy Specifications (cont.)
Function
Range
Resolution
Accuracy
± ([% of Reading] + [Counts])
Model
Continuity 600 Ω 1 Ω
Beeper on < 20 Ω, off > 250 Ω; detects
opens or shorts of 500 μs or longer.
110 PLUS, 115
Ohms
600.0 Ω
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.9 % + 2
0.9 % + 1
0.9 % + 1
0.9 % + 1
0.9 % + 1
5 % + 2
110 PLUS, 115
Diode test 2.000 V 0.001 V 0.9 % + 2
115
Capacitance 1000 nF
10.00 μF
100.0 μF
9999 μF
1 nF
0.01 μF
0.1 μF
1 μF
1.9 % + 2
1.9 % + 2
1.9 % + 2
100 μF - 1000 μF: 1.9 % + 2
>1000 μF: 5 % + 20
115
Lo-Z Capacitance (Power-
up option)
1 nF to 500 μF 10 % + 2 typical
115