12 Multimeter
USING MIN MAX FUNCTIONS
19
Recording Minimum and Maximum Reading with Elapsed Time
The MIN MAX with elapsed-time mode records the time (in hours and minutes)
between when MIN MAX was entered and the last high and low was recorded. Time is
kept to 99:59. OL is displayed for longer times.
1. To enable the MIN MAX elapsed-time clock, hold [j] down while moving the
slide-switch from OFF to the volts or continuity/ohms position.
2. Insert the test leads, and put the meter in volts or ohms.
3. Connect the leads to the circuit.
4. Press [j] to select MIN MAX. j is displayed, and time is set to 00:00.
5. Press [j] to step through the display sequence shown in Figure 8.
6. To exit, press [j] for 2 seconds, or change the measurement function.