175, 177, & 179
Calibration Information
4
Accuracy ± ( [ % of Reading ] + [ Counts ] )
Function Range
1
Resolution
Model 175 Model 177 Model 179
AC Volts
2
600.0 mV
6.000 V
60.00 V
600.0 V
1000 V
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
1.0 % + 3
(45 Hz to 500 Hz)
2.0 % + 3
(500 Hz to 1 kHz)
1.0 % + 3
(45 Hz to 500 Hz)
2.0 % + 3
(500 Hz to 1 kHz)
1.0 % + 3
(45 Hz to 500 Hz)
2.0 % + 3
(500 Hz to 1 kHz)
DC mV 600.0 mV 0.1 mV 0.15 % + 2 0.09 % + 2 0.09 % + 2
DC Volts
6.000 V
60.00 V
600.0 V
0.001 V
0.01 V
0.1 V
0.15 % + 2 0.09 % + 2 0.09 % + 2
1000 V 1 V 0.15 % + 2 0.15 % + 2 0.15 % + 2
Continuity 600 1 Meter beeps at < 25 , beeper turns off at > 250 ; detects
opens or shorts of 250 µs or longer.
Ohms 600.0
6.000 k
60.00 k
600.0 k
6.000 M
50.00 M
0.1
0.001 k
0.01 k
0.1 k
0.001 M
0.01 M
0.9 % + 2
0.9 % + 1
0.9 % + 1
0.9 % + 1
0.9 % + 1
1.5 % + 3
0.9 % + 2
0.9 % + 1
0.9 % + 1
0.9 % + 1
0.9 % + 1
1.5 % + 3
0.9 % + 2
0.9 % + 1
0.9 % + 1
0.9 % + 1
0.9 % + 1
1.5 % + 3
Diode test 2.400 V 0.001 V 1 % + 2
Capacitance 1000 nF
10.00 µF
100.0 µF
9999 µF
3
1 nF
0.01 µF
0.1 µF
1 µF
1.2 % + 2
1.2 % + 2
1.2 % + 2
10 % typical
1.2 % + 2
1.2 % + 2
1.2 % + 2
10 % typical
1.2 % + 2
1.2 % + 2
1.2 % + 2
10 % typical
AC Amps
(True RMS)
(45 Hz to 1 kHz)
60.00 mA
400.0 mA
(600 mA for 18 hrs)
6.000 A
10.00 A
(20 A for 30 s)
0.01 mA
0.1 mA
0.001 A
0.01 A
1.5 % + 3 1.5 % + 3 1.5 % + 3
1. All AC voltage and AC current ranges are specified from 5 % of range to 100 % of range.
2. Crest factor of 3 at full scale up to 500 V, decreasing linearly to crest factor 1.5 at 1000 V.
3. In the 9999 µF range for measurements to 1000 µF, the measurement accuracy is 1.2 % for all models.

Other manuals for Fluke 177

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 177 and is the answer not in the manual?

Fluke 177 Specifications

General IconGeneral
Frequency range0.00001 - 100 kHz
DC current range0.00001 - 10 A
DC voltage range0.0001 - 1000 V
Resistance range0.1 - 50000000 Ω
Resistance resolution0.1 Ω
Resolution (frequency)0.01 Hz
Resolution (AC current)10 µA
Resolution (DC voltage)0.1 mV
Basic accuracy (frequency)±(0.1% + 1)
Basic accuracy (DC voltage)±(0.09% + 2)
Basic accuracy (resistance)±(0.9% + 1)
Basic accuracy (capacitance)±(1.2% + 2)
Battery type9V
Battery voltage9 V
Number of batteries supported1
ManualYes
Weight and Dimensions IconWeight and Dimensions
Depth43 mm
Width90 mm
Height185 mm
Weight420 g

Related product manuals