Accuracy Specifications
7
Diode Test, Temperature, Resistance, Capacitance, Frequency, and Duty Cycle
Function Range Resolution
Accuracy
15B+ 17B+ 18B+
Diode Test
[1]
2.000 V 0.001 V 10 %
Temperature
50.0 °C –
400.0 °C
0 °C – 50.0 °C
-55.0 °C – 0 °C
0.1 °C _
2 % +1 °C
2 °C
9 % +2 °C
_
Resistance
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5 % + 3
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5 % + 3
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5 % + 3
Capacitance
[2]
40.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
5 % + 5
Frequency
[3]
(10 Hz – 100 kHz)
Hz
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
_ 0.1 % + 3 0.1 % + 3
Duty Cycle
[2]
1 % to 99 % 0.1 % _ 1 % typical
[4]
1 %
typical
[4]
[1] Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
[2] Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF
range).
[3] All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified.
[4] Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %.