True-rms Remote Display Digital Multimeter
Detailed Specifications
5
Temperature
Range Resolution Accuracy
[1]
-40 °C to +400 °C
-40 °F to +752 °F
0.1 °C
0.1 °F
±(1.0 % + 10)
±(1.0 % + 18)
[1] Temperature uncertainty (accuracy) does not include error of the thermocouple probe.
AC Current
Function Range Resolution
Accuracy
(45 – 500 Hz)
6.000 A 0.001 A
A ac
[1,2,3]
10.00 A 0.01 A
±(1.5 % + 3)
[1] All ranges are specified from 5 % of range to 100 % of range.
[2] Crest factor of 3 at 4000 counts, decreasing linearly to 1.5 at full scale.
[3] AC current >10 A is unspecified. 20 A continuous overload for 30 seconds maximum.
DC Current
Function Range Resolution Accuracy
6.000 A 0.001 A
A dc
[1]
10.00 A 0.01 A
±(1.0 % + 3)
[1] DC current >10 A is unspecified. 20 A continuous overload for 30 seconds maximum.
Capacitance
Range Resolution Accuracy
1000 nF 1 nF
10.00 μF 0.01 μF
100.0 μF 0.1 μF
9999 μF 1 μF
±(1.9 % + 2)
[1]
[1] >1000 μF: 5 % + 20
Diode
Range Resolution Accuracy
2.000 V 0.001 V ±(0.9 % + 2)
Frequency
AC coupled, 5 Hz to 50 kHz, for V ac; dc coupled, 45 Hz to 5 kHz for A ac switch position.
Range Resolution Accuracy
99.99 Hz 0.01 Hz
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
50.00 kHz 0.01 kHz
±(0.1 % + 2)