EasyManua.ls Logo

Fluke 233 - Detailed Specifications; DC Voltage, Conductance, and Resistance

Fluke 233
22 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
233
Calibration Information
4
Relative Humidity.......................................................... Maximum noncondensing
90 % at 35 °C
75 % at 40 °C
45 % at 50 °C
0 % to 70 % for 40 MΩ range
Battery Type
Meter base.................................................................. Three AA Alkaline batteries, NEDA 15A IEC LR6
Display module ........................................................... Two AA Alkaline batteries, NEDA 15A IEC LR6
Battery Life .................................................................... 400 hrs typical (Alkaline)
Shock ............................................................................. 1 Meter drop 6 sides per IEC 61010
Size (H x W x L) ............................................................. 5.3 cm x 9.3 cm x 19.3 cm
Weight ............................................................................ 604 g (1.3 lbs)
Safety Compliance........................................................ Complies with ANSI/ISA S82.01-2004, CSA 22.2 No. 61010-1-04 to 1000 V Measurement
Category III and 600 V Measurement Category IV.
Certifications ................................................................. CSA, TÜV (EN61010), P, ; (N10140),VDE, GOST
Detailed Specifications
For all detailed specifications:
Accuracy is specified for 1 yr after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy
specifications take the form of ±([ % of Reading ] + [ Number of least significant digits ]).
AC Voltage
AC conversions are ac-coupled and valid from 1 % to 100 % of range.
Accuracy
Range
[1]
Resolution
45 – 500 Hz 500 Hz – 1 kHz
600.0 mV 0.1 mV
6.000 V 0.001 V
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V
±(1.0 % + 3) ±(2.0 % + 3)
[1] Crest factor of 3 at 4000 counts, decreasing linearly to 1.5 at full scale.
DC Voltage, Conductance, and Resistance
Function Range Resolution Accuracy
mV dc
600.0 mV 0.1 mV
6.000 V 0.001 V
60.00 V 0.01 V
600.0 V 0.1 V
V dc
1000 V 1 V
±(0.25 % + 2)
600.0 Ω 0.1 Ω ±(0.9 % + 2)
6.000 kΩ 0.001 kΩ
60.00 kΩ 0.01 kΩ
600.0 kΩ 0.1 kΩ
6.000 MΩ 0.001 MΩ
±(0.9 % + 1)
Ω
40.00 MΩ 0.01 MΩ ±(1.5 % + 2)
Continuity
The beeper is guaranteed on <20 Ω, and guaranteed off >250 Ω, and detects opens or shorts of 500 μs or longer.

Other manuals for Fluke 233

Related product manuals