EasyManua.ls Logo

Fluke 5790B - AUX Input Characteristics; Absolute Wideband Specifications (5790 B;3, 5790 B;5, and 5790 B;AF)

Fluke 5790B
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Introduction and Specifications
Absolute Wideband Specifications (5790B/3, 5790B/5, and 5790B/AF) 1
1-17
AUX Input Characteristics
The AUX input can be used with the Fluke A40/A40A Series Current Shunts to make relative ac current measurements.
The 5790A-7001 A40/A40A Current Shunt Adapter and Cable are required. For optimal current measurements using
shunts, see the Operators Manual.
Input Resistance ............................................. 91 Ω ± 1 %
Operating Input Voltage .................................. 3 mV to 500 mV
Maximum Non-Destructive Input .................... 20 V rms
Absolute Wideband Specifications (5790B/3, 5790B/5, and
5790B/AF)
Voltage
[1]
Range
Frequency Range
Flatness
[2]
1 year ±
3 °C ± (% of
Reading
+ μV)
Flatness
[3]
Temperature
Coefficient ppm
/ °C
Absolute Specifcations
0 °C to 50 °C
[4]
± (% of Reading + μV)
Resolution
90 Days 1 Year 2 Years
2.2 mV
10 Hz - 30 Hz 0.10 + 0 75 0.5 + 1.2 0.6 + 1.5 0.8 + 2
30 Hz - 120 Hz 0.05 + 0 75 0.5 + 1.2 0.6 + 1.5 0.8 + 2
120 Hz - 1.2 kHz 0.05 + 0 75 0.5 + 1.2 0.6 + 1.5 0.8 + 2
1.2 kHz - 120 kHz 0.05 + 0 75 0.5 + 1.2 0.6 + 1.5 0.8 + 2
120 kHz - 500 kHz 0.07 + 1 75 0.5 + 1.2 0.6 + 1.5 0.8 + 2
0.1 μV
500 kHz - 1.2 MHz 0.07 + 1 75
1.2 MHz - 2 MHz 0.07 + 1 100
2 MHz - 10 MHz 0.17 + 1 200
10 MHz - 20 MHz 0.30 + 1 200
20 MHz - 30 MHz 0.70 + 2 400
30 MHz - 50 MHz
[5]
1.00 + 2 400
7 mV
10 Hz - 30 Hz 0.10 + 0 75 0.4 + 5 0.5 + 7 0.7 + 8
30 Hz - 120 Hz 0.05 + 0 75 0.4 + 5 0.5 + 7 0.7 + 8
120 Hz - 1.2 kHz 0.05 + 0 75 0.4 + 5 0.5 + 7 0.7 + 8
1.2 kHz - 120 kHz 0.05 + 0 75 0.4 + 5 0.5 + 7 0.7 + 8
120 kHz - 500 kHz 0.07 + 1 75 0.4 + 5 0.5 + 7 0.7 + 8
0.1 μV
500 kHz - 1.2 MHz 0.07 + 1 75
1.2 MHz - 2 MHz 0.07 + 1 100
2 MHz - 10 MHz 0.1 + 1 200
10 MHz - 20 MHz 0.17 + 1 200
20 MHz - 30 MHz 0.37 + 1 300
30 MHz - 50 MHz
[5]
0.5 + 1 300
22 mV
10 Hz - 30 Hz 0.10 75 0.4 + 10 0.5 + 13 0.7 + 16
30 Hz - 120 Hz 0.05 75 0.4 + 10 0.5 + 13 0.7 + 16
120 Hz - 1.2 kHz 0.05 75 0.4 + 10 0.5 + 13 0.7 + 16
1.2 kHz - 120 kHz 0.05 75 0.4 + 10 0.5 + 13 0.7 + 16
120 kHz - 500 kHz 0.07 75 0.4 + 10 0.5 + 13 0.7 + 16
0.1 μV
500 kHz - 1.2 MHz 0.07 75
1.2 MHz - 2 MHz 0.07 75
2 MHz - 10 MHz 0.1 100
10 MHz - 20 MHz 0.17 100
20 MHz - 30 MHz 0.37 200
30 MHz - 50 MHz
[5]
0.6 200

Table of Contents

Other manuals for Fluke 5790B

Related product manuals