EasyManuals Logo

Fluke 77 Series III User Manual

Fluke 77 Series III
59 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
Introduction and Specifications
Specifications
1
1-5
Table 1-1. Specifications
Maximum Voltage Between any
Terminal and Earth Ground
Rated voltage
Display Digital: 3,200 counts, updates 2.5/sec
Analog: 31 segments, updates 25/sec
Response Time of Digital Display V ac < 2 s
V dc < 1 s
< 1s to 320 k, < 2s to 3.2 M,
< 10 s to 32 M
Operating Temperature 0°C to 50°C
Storage Temperature -40°C to 60°C
Temperature Coefficient 0.1 x (specified accuracy)/°C
(<18°C or >28°C)
Electromagnetic Compatibility In
RF field of 3 V/m on all functions.
Total accuracy = Specified accuracy
+ 0.1% of range.
Relative Humidity
except 32 M range
32 M range only
0% to 90% (0°C to 35°C)
0% to 70% (35°C to 50°C)
0% to 80% (0°C to 35°C)
0% to 70% (35°C to 50°C)
Altitude Operating: 2000 meters
Storage: 12,000 meters
Battery Type 9 V NEDA 1604 or 6F22 or 006P,
or NEDA 1604A or 6LR61
Battery Life 2000 hrs typical with alkaline
1600 hrs typical with carbon zinc
Continuity Beeper 4096 Hz
Shock, Vibration per MIL-T-PRF 28800F Class III, Sinusoidal,
Non Operating
Size (H x W x L) 3.7 cm x 8.9 - 7.8 cm x 19 cm
(1.5 in x 3.5 - 3.1 in x 7.49 in)
Weight 365 g (12.9 oz)
Safety 600 V CAT III and 1000 V CAT II per
ANSI/ISA S82.01-1994, EN 61010-1: 1993,
CSA C22.2 No 1010.1-92, UL 3111-1.
EMC Regulations EN 61326-1 1997.
Certifications/Listings

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke 77 Series III and is the answer not in the manual?

Fluke 77 Series III Specifications

General IconGeneral
Diode TestYes
Continuity BeeperYes
Battery Type9V
Safety RatingCAT III 600V
DisplayLCD, 4000 counts
Voltage DC1000V
Voltage AC1000V
Current DC10A
Current AC10A
Resistance40 MΩ
Weight340 g