8021
B
ACCURACY
DC
(OVERALL) ...
20
kV to 30
kV
±2%
(calibrated at
25 kV)
UPPER
LIMIT
Changes
linearly from
2%
at 30
kV
to
4%
at 40
kV
LOWER
LIMIT
Changes
linearly from
2%
at 20 kV to 4% at 1
kV
ACCURACY
AC
(OVERALL)
.
. .
±5%
at 60
Hz
6-21. HIGH
FREQUENCY
PROBE (83RF)
6-22.
Introduction
6-23. The83RF
Probe
extends the
frequency
range
of
the DM M’s voltage
measurement
capability
to
include
100
kHz to 100
MHz
inputs from 0.25
to
30
V rms.The
probe
operates
in
conjunction
with
the
instrument’s dc
voltage ranges, and
provides a dc output
that
is
calibrated to be
equivalent to
the rms
value of a
sinewave input.
8-24. Specifications
FREQUENCY
RESPONSE
±i dBfrom
iOOkHzto i 00
MHz(relative toac/dc
transfer
ratio)
AC-TO-DC
TRANSFER
RATIO
RMS
Input
DC
Output
(23
±5°C)
(100
kHz)
0.25 -0.5V 0.25
-0.5V
±1.5
dB
0.5
-
2.0V 0.5
-
2.0V
±0.5
dB
2.0
-30V
2.0
-30V ±1.0
dB
EXTENDED
FREQUENCY
RESPONSE
Useful for
relative readings from 20 kHz to 250
MHz.
RESPONSE
Responds
to peak value of input; calibrated to
read the rms
value of
a
sine wave.
VOLTAGE
RANGE
0.25 to
30V
dc
MAXIMUM DC
INPUT
200V dc
TEMPERATU
RE CO EFFI Cl
ENT
(0
to
18°C, 28 to
50°
F)
±0.1 of
ac-to-dc transfer ratio
specifications per
°C
INPUT
CAPACITANCE <5
pF
6-25. HIGH
FREQUENCY
PROBE
(85RF)
8-26. Introduction
6-27. The Model
85RF High
Frequency Probe
allows measurements over a
frequency
range of 100
kHz to 500
MHz from
.25V to 30V rms. It
operates in conjunction with the
DM
M's dc
voltage ranges,
and provides a
dc output that is calibrated
to be equivalent to
the rms
value of a
sinewave
input.
6-28. Specifications
FREQUENCY
RESPONSE
100
kHz
to 100
MHz
±0.5
dB
100
MHz to 200
MHz ±1.0 dB
200
MHz
to
500
MHz ±3.0 dB
EXTENDED
FREQUENCY
RESPONSE
Useful
for relative
readings from 20 kHz. to 700
MHz.
RESPONSE
Responds to
peak value
of
input; calibrated to
read
rms value of a
sine wave.