867B/863
Users Manual
6-8
Changing the Configuration
U
Set up Self
Test
Exit
(wait 2 seconds)
Next
Item
<>
Restore
All
Save
Set up
NOTE
If no keys are pressed for 15 seconds after
the selector is turned to SET UP display
contrast returns to the default mid-scale
setting.
1. Beginning at the first line (LCD Contrast), press
1
to step through the other lines in this
display. Continue pressing to wrap back to the
top line.
At each configuration line, press
2
or
3
to
make your selection. Then press
1
to move
to the next line.
2. Press
4
to restore all lines on this
configuration display to their standard settings.
You have two choices at this point. First, you can
press
5
now to save the displayed
information as the power-up configuration.
Second, you can use the retrieved standard
configuration as a starting point, change some of
the settings as described above, and then store
your customized settings as the new power-up
configuration.
3. Press
5
to save all configuration settings
presently shown on the display into nonvolatile
memory. These settings become effective
immediately and are reestablished each time the
GMM test tool is powered on.
If you make SET UP changes and do not press
5
(Save Set up), the changes remain in effect only until
you turn the GMM off.