LinkIQ
Users Manual
20
Item Description Function
Remote ID label
Shows the Remote ID number used in the test and information
about the test.
Remote ID The Product detects the Remote ID and the wire
map test passes.
Remote ID The Product detects the Remote ID, but the wire
map test fails.
No Remote ID There is a short on the cable under test, so
the Product cannot detect the Remote ID. The wire map test
fails.
No Remote ID The test did not detect the Remote ID
because a Remote ID is not connected.
See Wire Map Screen Multiple Failures.
Wire and shield
identifiers (far
end)
Numbers: Indicates which wire from the near end maps to which
wire on the far end.
SH: Indicates the shield on the far end of a cable.
Wire map results
Shows the results of the wire map. See Wire Map Screen Multiple
Failures.
Wire and shield
identifiers (near
end)
A red box around a wire number indicates that the wire did not
pass based on the settings selected for the test.
A red box around SH indicates that the continuity of the shield
test did not pass.
Cable
performance
results
When a wire map passes, the results show:
The cable performance capability.
Whether the cable performance test passes (green) or fails
(red) based on the test limit selected for the test. If a wire
map fails, the segments show gray because the Product
cannot determine the cable performance capability.
Fail explanation
label
When a test fails, the label shows the reason why the test fails.
SAVE AS...
When there is memory available to save the result, tap SAVE
AS... to save the result. See Save a Test Result.
Table 8. Cable Test Results (cont.)