Ta b l e 9 shows a wire map of a cable test that failed for multiple reasons.
Table 9. Multiple Failures
Item Description
Pairs 1,2 are the shortest pair of the cable and open at 43.1 m.
The Product detected the Remote ID, and the wire map failed. The wires are not
wired correctly based on the settings selected for the test.
The wire map shows how the cable is wired. The wire map passes or fails based
on the settings selected for the test. For this test, the settings are set to test:
A straight through cable (Allow Crossover can be on or off to test a straight
through cable).
The continuity of the shield on the cable (Shield > )
The test limit is set to 1000BASE-T (1G) to verify a 4-pair cable.