Users Manual
4
Keep fingers behind the finger guards on the
probes.
Only use probes, test leads, and accessories
that have the same measurement category,
voltage, and amperage ratings as the Product.
Remove all probes, test leads, and
accessories before the battery door is
opened.
Remove all probes, test leads, and
accessories that are not necessary for the
measurement.
Do not exceed the Measurement Category
(CAT) rating of the lowest rated individual
component of a Product, probe, or accessory.
Do not use test leads if they are damaged.
Examine the test leads for damaged
insulation and measure a known voltage.
Do not use a current measurement as an
indication that a circuit is safe to touch. A
voltage measurement is necessary to know if
a circuit is hazardous.
Do not use the Product if it is altered or
damaged.
Do not use in CAT III or CAT IV environments
without the protective cap installed on test
probe. The protective cap decreases the
exposed probe metal to <4 mm. This
decreases the possibility of arc flash from
short circuits.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fluke ProcessMeter 787B and is the answer not in the manual?

Fluke ProcessMeter 787B Specifications

General IconGeneral
Battery life140 h
Battery sizeAA
Battery technologyAlkaline
Number of batteries supported4
ManualYes
Loop voltage1000 V
Drop proof up to1 m
Operating vibration2 G
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)-20 - 55 °C
Operating relative humidity (H-H)0 - 95 %
Weight and Dimensions IconWeight and Dimensions
Depth50 mm
Width100 mm
Height203 mm
Weight600 g