Safety Information
The following IEC symbols are used either on the test
set or in the manual:
Warning
To avoid possible fire, electric shock, or
personal injury:
Do not use the test set if it is damaged. Before you
use the test set, inspect the case. Look for cracks or
missing plastic. Pay particular attention to the
insulation surrounding the connectors.
Do not use around explosive gases or vapors, or in
a damp or wet environment when hazardous
voltage is present.
Do not connect the test set to lines that have more
than 140 V dc.
The test set meets IEC Measurement Category I.
CAT I equipment is designed to protect against
transients in equipment on circuits not directly
connected to MAINS. Under no circumstances
should the test leads of the test set be connected
to any CAT II, CAT III, or CAT IV rated circuit.
Do not use test leads if they are damaged. Examine
the test leads for exposed metal and damage to
the insulation. Make sure the wear indicator on the
cords does not show. The wear indicator is the
white layer below the outer, braided layer. Verify
the continuity of the test leads. To replace the test
leads, see page 31.
Do not connect the test set to voltages higher than
the maximum specified by the Measurement
Category (CAT) rating of the lowest-rated
individual component of the test set, test leads, or
accessory.
Use only accessories that are approved by Fluke
Networks.
Use only a 9 V battery, correctly installed, to supply
power to the test set.
Do not touch the exposed metal of the test clips.
Warning: Risk of personal injury. See the
manual for details.
Caution: Risk of damage or destruction to
equipment or software. See the manual
for details.
Warning: Risk of electric shock.
Conforms to relevant Australian EMC
requirements.
Conforms to relevant Canadian and US
standards.
Conforms to European Union directives.
Double Insulated - does not require
connection to earth ground.
Do not put products containing circuit
boards into the garbage. Dispose of circuit
boards in accordance with local
regulations.