Version Push buttons Alarm indications Pump well
indications
RTU status
indications
APX 761
Process controller
8 16 16 4
Power supply
This table shows the electrical data of the power supply.
Table 26
Item Specification
Supply voltage 24V DC -15% – +20%
Current consumption (no load) 1 A
Fuse 2 A
Digital inputs, max load 0.5 A
Analog inputs, max load 24V, 80 mA
Standards
Table
This table shows the approved standards for the unit.
Table 27
Standard
Number
EMC Emission Standard EN 61000-6-4
EMC Immunity Standard EN 61000-6-2
LVD EN 60947-1
CSA C22.2 No. 14-95
UL Recognized File Number E302902
Technical Data