Doc No: OMM50002312
Rev: C Page 24 of 54
Subject to contractual terms and conditions to the contrar
y, this document and all the information contained herein are the confidential and exclusive
property of FMC Technologies, and may not be reproduced
, disclosed, or made public in any manner prior to express written authorization by FMCTI.
Table 5: Fluid End Component List
Brass Petcock (Not Shown)
Fluid Cylinder Drain Plug
* Some piston holders are grooved for the o-ring; others require a seal holder situated on
the rod before the piston holder with the o-ring groove facing the piston holder
The illustrations above depict a typical pump with ball valves and clamp-on valve
covers. Alternate construction threaded style valve covers may be used on some
models.
The service procedures outlined in this manual are intended to describe the more
commonly used type of pump. Other configurations and minor design differences may
exist with different pumps. Some procedures may require slight adaptations as a result.