Doc No: OMM50002312 
Rev:  C Page 41 of 54 
Subject to contractual terms and conditions to the contrar
y, this document and all the information contained herein are the confidential and exclusive  
property of FMC Technologies, and may not be reproduced
, disclosed, or made public in any manner prior to express written authorization by FMCTI. 
30. Move the crankshaft back over to 
the opposite side and read 
bearing endplay as total indicator 
movement. Rotate the crankshaft 
several turns and repeat the effort 
to move the crankshaft in the 
direction described in this step. 
Repeat the dial indicator 
measurement. Remove or add 
shims as necessary to achieve 
proper endplay (.002" tight to 
.003" loose). Distribute shims 
equally on both bearing housings. 
Verify the endplay with the dial 
indicator per this procedure 
described before final assembly. 
31. Install the piston rod seal holder and seal retainer in the power frame per 
instructions in Section 10.4.1. The crankshaft should turn freely. 
32. Complete reassembly of pump. 
33. Torque all fasteners as outlined in Fastener Torque Requirements, Section 11.0 
of this manual.