Doc No: OMM50002312
Rev: C Page 41 of 54
Subject to contractual terms and conditions to the contrar
y, this document and all the information contained herein are the confidential and exclusive
property of FMC Technologies, and may not be reproduced
, disclosed, or made public in any manner prior to express written authorization by FMCTI.
30. Move the crankshaft back over to
the opposite side and read
bearing endplay as total indicator
movement. Rotate the crankshaft
several turns and repeat the effort
to move the crankshaft in the
direction described in this step.
Repeat the dial indicator
measurement. Remove or add
shims as necessary to achieve
proper endplay (.002" tight to
.003" loose). Distribute shims
equally on both bearing housings.
Verify the endplay with the dial
indicator per this procedure
described before final assembly.
31. Install the piston rod seal holder and seal retainer in the power frame per
instructions in Section 10.4.1. The crankshaft should turn freely.
32. Complete reassembly of pump.
33. Torque all fasteners as outlined in Fastener Torque Requirements, Section 11.0
of this manual.