Installation
Installing Levelers
1. Remove levelers from plastic bag packed inside refrigerator
(Fig.1).
2. Tip refrigerator back and screw levelers in all the way to stop
(they will extend 1/8" below base of REF).
3. Adjust levelers as needed to level REF in both directions. To
access levelers, remove the lower front panel. Turn levelers
clockwise to extend levelers.
Note: If you are using this in a food service application and installing in
accordance with NSF, you must seal the unit to the oor once it is
set in place. Place a 1/8" bead of NSF-approved silicone sealant
(not provided) around the base of the unit.
Fig. 1
Installing Shelves
1. Remove shelves packed as an accessory (Fig. 2).
2. Place top notch of shelf bracket into pilaster, then bottom notch.
Fig. 2
Installing Drawer
1. Remove drawer packed as an accessory (Fig. 3).
2. Install the two rollers to the threaded holes on each side of the
inside of the cabinet.
3. Hang one drawer slide on the each side of the cabinet by
holding the slide parallel to the bottom of the cabinet, tipping the
slide at a 45 degree angle, and pushing the slide over the two
rollers.
4. Once the drawer slides are installed, slide the two rear rollers of
the drawer into the slots on the top of the lower channel of the
slides. Tip up the front of the drawer and slide the back until the
front drawer roller lines up to slot. Drop the front drawer roller
into the channel and push the drawer all the way in the cabinet.
5. Test operation of the drawer by sliding the drawer all the way
out, then back in.
Fig. 3
Reversing the Door Swing – Optional
Tools needed:
§ #2 Phillips head screwdriver
§ Flat-head screwdriver
§ Awl
§ Gloves
§ Safety glasses
1. Remove kick panel* (Fig. 4). Disconnect the door sensor switch
wires and grey control wire.
* If the unit has a keypad lock, the door must be open to remove the kick panel.
2. Remove wire and strain relief from kick plate (Fig. 4).
Fig. 4
4 REF4P and REF5P Undercounter Refrigerators