Manual # 26-0302000-00 / Revision E ImagePRO – Multi Format Image Processor
75
ISYNCSLICE in nnn
Description: Adjusts the Input Sync Slice Threshold selection.
Parameters: in - Input chnl [1-3]
nnn - Sync Slice Threshold [20 – 280mV (in steps of 10)]
Query:
ISYNCSLICE? in
Returns the Input Sync Slice Threshold selected for the specified input channel in the format
= nnn
Example: ISYNCSLICE 1 60 (Sets Sync Slicer threshold to 60mV for channel 1.)
ISYNCSLICE? 1 (Queries Input Sync Slicer threshold for channel 1)
Command:
ITYPE in mode
Description: Sets the Input Type. Note: If Auto Acquire is On, setting Input type with this command may be
overridden. Input Type DVI is only available on input channel 1 for ImagePRO-SDI and ImagePRO-
HD units.
Parameters: in - Input chnl [1-3]
mode - Mode [0|1|2|3], RGB | YPbPr | NTSC/PAL/SECAM | DVI (DVI available only on chnl 1 for
ImagePRO-SDI and ImagePRO-HD units)
Query:
ITYPE? in
Returns the Input Type selected for the specified input channel in the format
= mode
Example: ITYPE 1 2 (Sets Input type to YPbPr on input channel 1.)
ITYPE? 1 (Queries Input type for channel 1)
Command:
IVATV nnnn
Description: Set Input Vertical Active. The minimum and maximum limit is dependent on the input resolution.
Parameters: nnnn - Input Vertical Active: nnnn[(Actual Input V Active * 2/10, absolute minimum of 150) –
+(Actual Input V Active *6/5, absolute maximum of Input V Total – Input V Sync)]
Query:
IVATV?
Returns the Input’s Vertical Active value in the format
= nnnn.
Example: IVATV 768 (Set Input Vertical Active to 768)
IVATV? (Queries Input Vertical Active)
Command:
IVPOS nnnn
Description: Set Input Vertical Position. The minimum and maximum limit is dependent on the input
resolution.
Parameters: nnnn - Input Vertical Position: nnnn[(Input V Sync) - +(Input V Total – Input V Active)]
Query:
IVPOS?
Returns the Input’s Vertical Position value in the format
= nnnn
Example: IVPOS 35 (Set Input Vertical Position to 35)
IVPOS? (Queries Input Vertical Position)
Command:
IVTOTAL?
Description: Query Input Vertical Total.
Parameters: None
Returns: nnnn - Input Vertical Total