Thermostat
SYSTEM PARAMETERS
CODE SETTING MODE DATA RANGE
P01
Type of electric heating
0: Auto Mode - 1: Force
Default :0
P02
Duration of electric heating
3 to 180 minutes,
Default : 20 minutes
P03
Electric heating temperature
15°C to 30°C (59°F to 86°F)
Default : 23°C (73°F)
COOLING AND HEATING TEMPERATURES
MODEL DEFAULT VALUE DATA RANGE
COOLING
24°C (75°F) 16°C to 31°C (61°F to 88°F)
HEATING
27°C (81°F) 16°C to 31°C (61°F to 88°F)
AUTO
24°C (75°F) 16°C to 31°C (61°F to 88°F)