18
If a localized fire develops either inside or outside of the machine, immediately take the
following actions.
If the fire is inside the Fuse Blast:
1. Immediately disconnect the machine from its power source.
2. If possible, open the blast chamber door by releasing the chamber door latch.
3. Use an ABC fire extinguisher to cover the aected area generously.
If the fire is too large to control:
1. Immediately leave the area and close the door of the room behind you.
2. Evacuate the building according to your organization’s emergency protocols.
3. Call emergency services once you have reached a safe distance from the fire.
3.4.2 Powder
In an emergency involving powder, always refer to the safety data sheet (SDS) and/or
seek help from a medical professional.
3.4.3 Air compressor
The Fuse Blast requires a compressed air supply that can support 10 SCFM airflow at 90 psi
or 285 SLPM at 6 bar and regulate pressure input between 90–120 psi / 6-8 bar, equal to a 4
hp compressor motor. 4 hp motors typically require 230 VAC.
Follow all guidelines laid out by the air compressor supplier.