Program Features
See Programming Section for more detailed information.
High and Low Flow Warning (Codes 315 and 316)
When the ow rate is above the programmed high ow value, a ashing -HI- is
shown in the digital display. When the ow rate is below the programmed low ow
value, a ashing -LO- is shown in the digital display.
Flow Cutoff (Codes 318 or 319)
The digital display indicates 0 when the ow rate is below the programmed ow
cutoff value.
TOTAL Button
The TOTAL button performs two functions, display total ow for a discharge or
reset the totalized ow value to 0 (if totalizer reset function is set to YES).
Display Total Flow
When the TOTAL button is pressed and released the digital display shows the total
accumulated ow and the TOTALx100 LED is on. (The value shown is times 100.)
Press and release the TOTAL button again to show normal ow rate.
Reset Total Flow to 0
The totalizer reset (code 317) has two program settings, YES or no. (Refer to
Programming Section). To enable the reset function the program totalizer reset is set
to YES.
Total ow resets and starts from 0 when power is applied to the control module.
Flow total is reset to 0 during operations by displaying the total ow and then pressing
and holding the TOTAL button until the display shows 0.