Error Code E202
An invalid program code has been entered. Re-enter the program code when the
digital display resets.
Error Code E204
There is no signal from the sensor. This code is displayed only when in a calibration
program. Troubleshoot the sensor and the associated wiring.
Error Code E206
A selected calibration point is to close to the previous point. (There is less than 5%
difference between two calibration points.) Select a different point to continue with
the calibration procedure.
Error Code E208
There is a failure with the internal memory of the module. Contact factory if this
error code is displayed.
Error Code E210
The number of available calibration points have been exceeded. Exit the
calibration program.
Exit Program Access Mode
Press and hold the MODE button and then press the TOTAL button and hold them
until the display shows four dashes. Release the buttons and enter a new code, or after
ve seconds the program times out and returns to normal operation.