29
No. Text in display Meaning / causes Remedy
11 - - -
12 - - -
13 Mains failure Supply voltage inter- Check connection
rupted or too low conditions
14 - - -
15 Power rating Power consumption of -
exceeded the fitting exceeds the
rating of the FRIAMAT
®
More Fault messages
An example of what is shown on the display:
By pressing the INFO button you will get information on the fault in plain
language
Warning messages :
Resistance
outside tolerance
Fault 3 INFO ?
Text in display Instruction / Remedy
Faulty or damaged bar code Use a new bar code from an identical
fitting or correct the manually entered code
Memory full Print out the log
Memory empty If the memory is empty no printout
is possible
Printer not ready Check whether the output device (printer,
Memory Box, PC with FRIATOOL II) is
connected correctly