28
No. Text in display Meaning / causes Remedy
1 - - -
2 Temperature Ambient temperature If necessary set up a tent
outside range outside the permitted
range
3 Resistance Electrical resistance of Check contacts for firm
outside tolerance the fitting is outside seating / dirt
the tolerance Clean contacts if necessary
If necessary replace fitting
4 Fitting winding Short circuit in the wire Replace fitting, send in
short circuit winding of the fitting for examination
5 Fitting winding Current flow interrupted Check the connection of
open circuit the fusion plug on the fitting.
If OK replace the fitting and
send in for examination
6 Voltage outside Unacceptable deviation Inform Authorised Service
tolerance of the fusion voltage Centre
7 Fault in the Malfunction in the Make a note of the fault
a..z operating system FRIAMAT
®
hardware or classification (a...z) and
software inform Authorised Service
Centre
8 Mains voltage Mains voltage outside Extension cable too long or
outside range the permitted range its cross section too small.
during fusion Check the voltage and
connection conditions of
the generator
9 Frequency outside Frequency outside the Check the frequency of the
range permitted range during generator voltage
fusion
10 Fusion interrupted Fusion broken off by -
pressing the STOP button
Fault messages
7.5 Fault messages / Warning messages
If irregularities occur during the fusion process then your FRIAMAT
®
model
will show suitable fault messages in the display