7
In the event of doubt (e.g. when purchasing new) ask the authorised service
centre or request the “Positive Generator List” from FRIATEC AG.
Only use generators whose operating frequency lies within the range from
45 - 66 Hz.
First start the generator and let it run for half a minute. Set the off-load voltage
if necessary and limit it to the voltage specified in the technical data. !
Generator (mains) fuse max. 16 A (slow acting)
IMPORTANT ! Before starting the fusion process always check the input
voltage for your FRIAMAT
®
model from the Technical
Data (See Section 2.1 and 4.7)
If using an extension cable make sure the cross section is adequate:
- 2.5 mm
2
up to 50 m and
-4 mm
2
up to 100 m length.
Always unroll the cable fully before use. ! Do not connect any other equipment
to the same generator whilst fusion is taking place ! At the end of the fusion
operation first disconnect the power cable to the generator and then shut off
the generator.
DANGER ! Risk to life ! Never open your FRIAMAT
®
model whilst it is
connected to the power supply !
The fusion units of the FRIAMAT
®
Family are must only be opened by
specialist personnel from a recognised service centre !
1.7 Emissions
The (equivalent) continuous noise level from all fusion units of the FRIAMAT
®
Family is below 70 dB(A). When working in a quiet environment the effect of
the signal tone on the “Loud” setting is very loud. For this reason the signal
tone is adjustable (loud / quiet)