Text in display Instruction / Remedy
Let the unit cool down Protective function which prevents
overheating of the equipment. Switch off
the unit and allow it to cool down until
the warning message is no longer
displayed after switching on.
Service date exceeded Inform Authorised Service Centre.
Have the equipment serviced.
Voltage .... V; Frequency .... Hz Readjust generator then acknowledge
with the STOP button (See Section 4.7)
No text, just a continuous acoustic Supply voltage too low
tone
N.B. Double fusion If a fitting is to be fused twice the contact
plugs of the fusion unit must be pulled off
the fitting after the first fusion and the
fitting allowed to cool down (see the
instructions for use from the fitting
manufacturer)
8. Appendix
8.1 Recommended accessories (options)
- Memory Box to transfer fusion data
- FRIATOOL II for electronic processing of the fusion data
- Operator pass
- Scanner
- Remote start pass
- Fusion cable extension
- Infrared remote control