4.6 Switching off the power supply
WARNING
When turning off the main switch in automatic mode:
Serious combustion faults leading to serious accidents are possible.
Before turning off the main switch:
Switch boiler off by tapping “Boiler OFF”
The boiler follows the shutdown procedure and switches to "Boiler
off“ status after the cleaning cycle
Turn off the main switch
Boiler controller is switched off
The components powered via the control cabinet are powered down
CAUTION: the expansion switch cabinet, which has its own power supply, is
still live.
NOTICE! Frost protection function is no longer active!