Troubleshooting
Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestraße 12, A-4710 Grieskirchen, Austria Page 41
Tel +43 (0) 7248 606-0 Fax +43 (0) 7248 606-600 info@froeling.com www.froeling.com
B0190806
Cause of error Error correction
Outdoor sensor temp.
false
036 W • Sensor signal damaged Check sensor and sensor cable
DHW temp. false 006 W • Sensor signal damaged Check sensor and sensor cable
DHW temp.2 false 037 W • Sensor signal damaged Check sensor and sensor cable
Clean /check burner 049 W Signals successful automatic troubleshooting
NOTE: can only be cleared by checking and cleaning the burner
Acknowledge warning
After you have done this, open the insulating door and
combustion chamber door
Clean embers, fuel and slag from the pellet burner (see
chapter on maintenance)
Clean the flue gas guide in the boiler up to the mouth of the
chimney
Empty the ash drawer
Stoker error 030 F Gravity shaft level sensor still
recognises material after 10
minutes of stoker running
time:
• Bridge formation in the
gravity shaft
• Sensor incorrectly set
• Stoker not feeding
Break up the bridge of fuel,
remove foreign bodies if
necessary
Readjust the sensor
Check stoker drive
Remote control 1 error 004 W • Sensor signal damaged Check sensor and sensor cable
Remote control 2 error 005 W • Sensor signal damaged Check sensor and sensor cable
Remote control 3 error 025 W • Sensor signal damaged Check sensor and sensor cable
Remote control 4 error 026 W • Sensor signal damaged Check sensor and sensor cable