2.4.3 Fuels permitted under certain conditions
Wood briquettes
Wood briquettes for non-industrial use with a diameter of 5-10 cm and 5-50 cm long.
EU: Fuel as per EN ISO 17225 - Part 3:
wood briquettes class B / D100 L500 Form 1 - 3
Additional for
Germany: Fuel class 5a (§3 of the First Federal Emissions Protection Ordinance
(BImSchV) - applicable version)
When burning wood briquettes use the settings for extremely dry fuel
Wood briquettes must be heated up with firewood as per EN ISO 17225-5
(at least two layers of firewood under the wood briquettes)
The fuel loading chamber must not be filled more than 3/4 full, as the wood briquettes
expand during combustion
Even when using the settings for dry fuel, burning wood briquettes can cause
combustion problems. In such cases, repairs must be carried out by qualified staff.
Please contact Froling customer services or your installer.
Note on standards
Notes on
use
2
Safety
Permitted uses
12 Froling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com

Table of Contents

Other manuals for Froling S3 Turbo

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Froling S3 Turbo and is the answer not in the manual?

Froling S3 Turbo Specifications

General IconGeneral
BrandFroling
ModelS3 Turbo
CategoryBoiler
LanguageEnglish

Related product manuals