2.10 Emergency procedure
2.10.1 Overheating of the system
If the system overheats and the safety devices fail, proceed as follows:
NOTICE! Do not under any circumstances switch off the main switch or disconnect the
power supply.
Keep all the doors on the boiler closed
Open all mixing valve taps, switch on all pumps.
The Froling heating circuit control performs this function in automatic operation.
Leave the boiler room and close the door
Open any available radiator thermostat valves
If the temperature does not drop:
Contact the installer or Froling customer services
⇨ See "Addresses" [page 45]
2.10.2 Smell of flue gas
DANGER
If you smell flue gas in the boiler room:
Inhaling toxic flue gas can be fatal!
If you smell flue gas in the room where the boiler is installed:
Keep all the doors on the boiler closed
Shut down the boiler according to procedure
Ventilate the room where the boiler is installed
Close the fire door and doors to living areas
2.10.3 Fire in the system
DANGER
In case of fire in the system:
Risk of death by fire and poisonous gases
Emergency procedure in case of fire:
Leave the boiler room
Close the doors
Inform the fire department
2
Safety
Emergency procedure
20 Froling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com

Table of Contents

Other manuals for Froling S3 Turbo

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Froling S3 Turbo and is the answer not in the manual?

Froling S3 Turbo Specifications

General IconGeneral
BrandFroling
ModelS3 Turbo
CategoryBoiler
LanguageEnglish

Related product manuals