❒ Fill the fuel loading chamber according to the expected consumption and close the
fuel loading chamber door
⇨ See "Determining the right amount of fuel" [page
23]
❒ Open the pre-heating door, insert scrunched up paper and light
If the underpressure from the induced draught fan is too strong for the firing material to
be ignited:
❒
Press the Down arrow in the navigation keys (5.3) briefly
➥ The induced draught fan switches off
❒ Light the firing material
❒ Press the Up arrow in the navigation keys (5.3) briefly
➥ The induced draught fan switches on
❒ Leave the pre-heating chamber door open for approximately 5 minutes
➥ A bed of embers forms
❒
Close the pre-heating chamber door and the insulated door
➥ The flue gas temperature must be > 130°C
3
Operating the system
Heating the boiler