30
If the battery voltage selection window does not open, then the battery is in a state of ex-
treme deep-discharge (less than 2 V). In this case, buffering is not permitted. We recom-
mend that the battery is replaced.
WARNING!
Danger following ignition of oxyhydrogen caused by sparks resulting from the
charging leads being disconnected too soon.
This can result in serious injury and damage to property.
► Before disconnecting the charging leads, press the Stop/Start button to finish buffering.
Disconnect the charger
- Disconnect the black charging lead from the negative pole (-) of the battery
- Disconnect the red charging lead from the positive pole (+) on the battery
Interrupting Buff-
ering mode
NOTE!
Danger from disconnecting or unplugging the charging leads during buffering.
This can result in damage to connection sockets and connecting plugs.
► Do not disconnect or unplug charging leads while buffering.
Resuming buffer-
ing
Confirm the selection using the Stop/Start key
To cancel Buffering mode:
- Press the Stop/Start key
5
6
7
Press the Stop/Start key during buffering
- The charging process is interrupted
1
Press the Stop/Start key
- Buffering is resumed
2