Available charac-
teristics
Charging characteristic IUoU:
I
1
= Main charging current
U
1
= Final charging voltage
U
2
= Conservation charging voltage
Operating mode Battery Charac-
teristic
I
1
U
1
[6/12/24V] I
2
U
2
[6/12/24V] Ex.
Charging WET IUoU 35* 7.2/14.4/28.2 - 6.75/13.5/27 Yes
AGM 6.84/13.68/
27.36
GEL 7.05/14.1/28.2
USER 2-30 1.9-29.9
Buffering (Trickle)
mode
All IU 35 6.75/13.5/27 - - Yes
Refresh WET IUIoU 35* 7.2/14.4/28.8 4 6.75/13.5/27 No
AGM 2 6.84/13.68/
27.36
GEL 7.05/14.1/28.2
USER IUa 35** 2-34 - - Yes
Power supply
mode
None IU 35 6.75/13.5/27 - - Yes
Battery changing All IU 35 6.75/13.5/27 - - No
I
1
Main charging current [A]
maximum device current: 35 A
* 20 A per 100 Ah of specified battery capacity
** 10 A per 100 Ah of specified battery capacity
U
1
Final charging voltage [V]
I
2
Recharging current [A per 100 Ah of specified battery capacity]
U
2
Conservation charging voltage [V]
Automatic switchover to pulse charge conservation after 12 hours, apart
from user application in Expert mode
Ex. Adjustable final charging voltage and conservation charging voltage in Ex-
pert mode. For trained professionals only
I
1
U
1
U
2