40
- Boost (on/off), factory setting: on
Boost on: shorter charging time resulting in the battery being fully charged sooner. The
full 35 A of power available from the device is applied if parallel consumers are detect-
ed (car radio, etc.).
Boost off means that a conventional workshop charging process is followed (fixed
charging current of 20 A per 100 Ah of specified battery capacity). Parallel consumers
(car radio, etc.) are not detected in this case.
- Expert (on/off)
Enter the following to activate Expert mode (Expert on):
Code number 1511
Expert mode (Expert on) allows a user application to be specified for WET, GEL and
AGM batteries when the device is in charging mode. The following may be configured:
Final charging voltage
Conservation charge voltage
- Buffering mode
Constant voltage may be adjusted
- Refresh
Enter the following to alter the Refresh setting:
Code number 1511
Final charging voltage and duration may be adjusted
- Power Supply mode
Constant voltage may be adjusted