45
EN
Status codes in the event of device fault:
50 Cause: Device output fuse faulty
Remedy:
- Contact your authorised service centre
51 Cause: Secondary temperature is outside permissible range
Remedy:
- Contact your authorised service centre
52 Cause: Current regulator faulty
Remedy:
- Contact your authorised service centre
53 Cause: External temperature sensor faulty
Remedy:
- Replace external temperature sensor
60 Cause: Invalid characteristic number
Remedy:
- Contact your authorised service centre
61 Cause: Characteristic block invalid
Remedy:
- Contact your authorised service centre
62 Cause: Incorrect checksum of calibration values
Remedy:
- Contact your authorised service centre
63 Cause: Incorrect device type
Remedy:
- Contact your authorised service centre