32
Contrast
Set the contrast on the display
Since the contrast is temperature-dependent, when the ambient conditions change it may 
be necessary to adjust the 'Contrast' menu item.
Illumination
Initial setting for display illumination
The 'Illumination' menu item only relates to the display backlighting.
Energy yield Setting
- of an OFFSET value for the total energy display 
- of a measuring offset factor for the day, year and total energy display
- of the currency
- of the feed-in tariff
ON: DATCOM mode is always in effect. The inverter supplies 12 V continuously 
to power the Fronius Solar Net. The display is always active.
IMPORTANT! If DATCOM night mode is set to ON or AUTO when there are 
Fronius Solar Net components connected, then the inverter's current con-
sumption during the night will increase to around 7 W.
OFF: DATCOM will not run at night, the inverter will not need any AC current in 
order to supply power to the Fronius Solar Net.
The display is switched off during the night and the Fronius Datamanager is 
not available.
Setting range 0 - 10 
Factory setting 5
Setting range AUTO / ON / OFF 
Factory setting AUTO
AUTO: Display backlighting is activated by pressing any key. If no key is pressed for 
2 minutes, the display backlighting will go off again.
ON: The display backlighting remains permanently on when the inverter is 
switched on.
OFF: The display backlighting is permanently switched off.
Setting range Meter deviation / Meter calibration / Currency / Feed-in tariff
Meter deviation
Input of a value for the fed-in energy that will be added to the energy currently fed in (e.g. 
carry-over value when replacing an inverter)
Unit Wh / kWh / MWh
Setting range Five digits
Factory setting 0