11
EN
Connecting the KD Supply 2500 to the cooling unit 
and power source
Safety
WARNING!
An electric shock can be fatal. 
If the machine is plugged into the mains electricity supply during installation, there is a high 
risk of very serious injury and damage. Only carry out work on the machine when
► the mains switch is in the „O“ position,
► the machine is unplugged from the mains.
Connecting the 
KD Supply 2500 
to the cooling unit 
and power source
Turn the power source mains switch to 
the „O“ position
Unplug power source mains plug
Remove protective cover from the un-
derside of the power source
Firmly press four M5 hexagonal nuts 
(supplied with the KD Supply 2500) 
from the inside into the hexagonal 
recesses (1) in the fastening bars
If a cooling unit is present:
Remove the protective cover from the 
underside of the KD Supply 2500
FIrmly press four M5 hexagonal nuts 
(supplied with cooling unit) from the in-
side into the hexagonal recesses (2) in 
the fastening bars
Hold the KD Supply 2500 over the coo-
ling unit
Pull the KD Supply 2500 connector as 
far as possible through the opening on 
the underside of the power source
Establish connection between KD Sup-
ply 2500 and cooling unit
CAUTION!
Risk of short circuit from kinked or damaged cables.
► When positioning the KD Supply 2500, ensure that the cables are not kinked.
Carefully place the KD Supply 2500 on the cooling unit
(1)
(1)
(1)
(1)
(2)
(2)
(2)
(2)
1
2
3
4
5
6
7
8
9
10